SWFSH Series Sine Wave Filter
Home » Products » Power Quality-Harmonic filter » SWFSH Series Sine Wave Filter

loading

Share to:
facebook sharing button
twitter sharing button
line sharing button
wechat sharing button
linkedin sharing button
pinterest sharing button
whatsapp sharing button
sharethis sharing button

SWFSH Series Sine Wave Filter

  • converting PWM wave into sine wave(protecting motor,transformer etc)

  • SWFSH-9/0.48

  • output side of VFD

  • Sanhe

Availability:

PDF Export

Product introduction

The sinusoidal filter is mainly used to solve the harmonic problem at the output end of VFD. It converts the PWM wave of the motor into smooth sine wave with low residual ripple voltage, prevents damage to the winding insulation of the motor ,reduces the phenomenon of distributed capacitance and distributed inductance resonance caused by the cable length, and reduces the audible noise of the motor. At the same time, it can realize the long-distance transmission of VFD.


Feature

1. An L-C power filter circuit with:

    A 3-phase reactor

    High-endurance, harmonic-rated capacitors

    Compression terminals for ease and integrity of all power wiring

    Thermal switches on reactor is optional

    Suitable for all lead lengths extending up to 3,000 feet

2. High performance H grade insulation material is used.

3. Withstanding extremely high Dv/Dt voltage shock.

4. Product loss is small, audible noise is small.

5. Strong anti-electromagnetic ability, short time overload ability.

6. Improving power quality, harmonic voltage distortion content reduced to 5%



Product Description

SWFSH is a 3-phase low-pass sine wave filter designed and developed to deliver conditioned power to motor loads driven by PWM drives with switching frequencies from 2 kHz to 16 kHz. Any drive control parameter which has the effect of reducing the carrier or switching frequency below 2 kHz at any time must be disabled. Some sine wave or long lead mode drive parameters or operating modes can have this effect. This filter is suitable for VFD drives configured to Volts per Hz modes only. Available for three phase voltage systems up to 460/480 Volts, the SWFSH is a passive LC filter connected in series with the output terminals of the variable frequency drive. This design removes the carrier frequency distortion from the output voltage waveform resulting in a nearly pure sine wave voltage profile.

SWFSH sine wave filter reduces the effects of the reflected wave phenomenon (dV/dt),

which can cause motor heating, insulation damage, and excessive audible noise. The reduction

of high frequency VFD output currents extends the life of motors and transformers and eliminates

the need for special motor cables. The SWFSH reduces VFD ground fault problems and

noise interference in transducer signals caused by stray high frequency harmonic currents.




Model Selection


Model Number

VFD

HP

VFD

KW

Current Rating (Amps)

Size (WxDxH)

SWFSH-9/0.48

5

3.7285

9

500x400x1000

SWFSH-12/0.48

7.5

5.59275

12

500x400x1000

SWFSH-16/0.48

10

7.457

16

500x400x1000

SWFSH-23/0.48

15

11.1855

23

500x400x1000

SWFSH-30/0.48

20

14.914

30

500x400x1000

SWFSH-35/0.48

25

18.6425

35

500x400x1000

SWFSH-45/0.48

30

22.371

45

500x400x1000

SWFSH-55/0.48

40

29.828

65

500x400x1000

SWFSH-65/0.48

50

37.285

65

500x400x1000

SWFSH-80/0.48

60

44.742

80

600x600x1250

SWFSH-110/0.48

75

55.9275

110

600x600x1250

SWFSH-130/0.48

100

74.57

130

800x800x1500

SWFSH-160/0.48

125

93.2125

160

800x800x1500

SWFSH-200/0.48

150

111.855

200

800x800x1500

SWFSH-250/0.48

200

149.14

250

800x800x1500

SWFSH-305/0.48

250

186.425

305

800x800x1500

SWFSH-362/0.48

300

223.71

362

800x800x1500

SWFSH-420/0.48

350

260.995

420

800x800x1500

SWFSH-480/0.48

400

298.28

480

800x800x1500

SWFSH-540/0.48

450

335.565

540

800x800x1500

SWFSH-600/0.48

500

372.85

600

800x800x1500

SWFSH-750/0.48

600

447.42

750

800x800x1500


Parameter



Current Ratings

240 V: 5 – 248 Amps

480 V: 5 – 1080 Amps

600 V: 8 – 500 Amps

Intermittent overload current of 150% for 1 minute out of every 60 minutes


VFD Output Voltage

240 V, 480 V and 600 V, 3-phase, at fundamental base frequency configured to Volts per Hz


VFD Output Frequency Up to 65 Hz

VFD Carrier Frequency 2 kHz to 16 kHz


Filter Performance

Maximum peak voltage of output waveform

480 V models: 815 V,

600 V models: 1,018 V

Maximum dV/dt of output waveform

480 V models: 5 V/μs;

600 V models: 6 V/μs


Environmental Conditions

Maximum Elevation

6,600 feet (2,000 m), derating required for operation above this level

Ambient Operating Temperature Range


-30°C (-22°F) to 40°C (104°F)

Cooling provisions required for operation above this temperature


Ambient Storage Temperature Range

-40°C (-40°F) to 50 °C (122 °F)

Maximum Humidity 95%, non-condensing


Reference Technical Standards

GB/T 15576-2020

GB/T 12326-2008

GBT 12747.1-2017


Sine Wave Filter Effective

图片1


Ordering Guide

Matched VFD specification power

Switching frequency of VFD

Power supply conditions should be :unbalance<1%,THDv<2%

Altitude:<2000m; the capacity reduction is greater than2000m

Ambient temperature:-20~+50°C


Previous: 
Next: 

About Us

We have been specialized in power quality,EnMS and Electrical engineering. We take advantages of lean production, product design, engineering management, project service etc.

Quick Links

Product Category

Contact Us

Tel: +86-13502854349
Whatsapp: +86-13418990147
E-Mail: yvonne.zhang@samwha-cn.com

Subscribe Now

Copyright© 2023 Sanhe Power Tech (Shenzhen) Co., Ltd. All Rights Reserved.| Sitemap  | Support By Leadong