Compensate unbalanced three phase for three phase208-690V/50(60)Hz system
SUAR
Wall mounted / Floor standing
Sanhe
Availability: | |
---|---|
PDF Export | |
Specific information:
SUAR is helpful to effectively compensate unbalanced three phase,bidirectional fast reactive power,real-time and stable system voltage.real-time monitoring of the load side of the current, and DSP processing and analysis of this data and calculation of equilibrium required for each phase of the compensation current, then drive the IGBT output, to achieve the object.
Feature:
Main power module inverter adopts international famous brand IGBT devices;
A variety of control modes can be set freely according to demand;
With full protection features including overload, overcurrent, short circuit, the system starts with self-diagnostic function;
Start with a buffer control circuit can be avoided from the start instant excessive input current ;
Divided with independent control, both to balance the load current, but also to achieve single-phase, three-phase reactive power compensation;
Commissioning maintenance is simple, easy to transport.
Order Guide:
Transformer (kVA) | 2nd Electricity Side Voltage (kV) | 2nd Electricity Side Current(A) | Unbalanced Current (A) | SUAR Capacity (A) |
80 | 0.4 | 115 | 57.5 | 50 |
100 | 0.4 | 150 | 75 | 50 |
125 | 0.4 | 180 | 90 | 75 |
160 | 0.4 | 230 | 115 | 75 |
200 | 0.4 | 300 | 150 | 100 |
250 | 0.4 | 360 | 180 | 150 |
315 | 0.4 | 455 | 227.5 | 150 |
400 | 0.4 | 577 | 288.5 | 200 |
500 | 0.4 | 722 | 361 | 250 |
630 | 0.4 | 909 | 454.5 | 300 |
Specific information:
SUAR is helpful to effectively compensate unbalanced three phase,bidirectional fast reactive power,real-time and stable system voltage.real-time monitoring of the load side of the current, and DSP processing and analysis of this data and calculation of equilibrium required for each phase of the compensation current, then drive the IGBT output, to achieve the object.
Feature:
Main power module inverter adopts international famous brand IGBT devices;
A variety of control modes can be set freely according to demand;
With full protection features including overload, overcurrent, short circuit, the system starts with self-diagnostic function;
Start with a buffer control circuit can be avoided from the start instant excessive input current ;
Divided with independent control, both to balance the load current, but also to achieve single-phase, three-phase reactive power compensation;
Commissioning maintenance is simple, easy to transport.
Order Guide:
Transformer (kVA) | 2nd Electricity Side Voltage (kV) | 2nd Electricity Side Current(A) | Unbalanced Current (A) | SUAR Capacity (A) |
80 | 0.4 | 115 | 57.5 | 50 |
100 | 0.4 | 150 | 75 | 50 |
125 | 0.4 | 180 | 90 | 75 |
160 | 0.4 | 230 | 115 | 75 |
200 | 0.4 | 300 | 150 | 100 |
250 | 0.4 | 360 | 180 | 150 |
315 | 0.4 | 455 | 227.5 | 150 |
400 | 0.4 | 577 | 288.5 | 200 |
500 | 0.4 | 722 | 361 | 250 |
630 | 0.4 | 909 | 454.5 | 300 |