HVCA series Pole Mounted medium voltage automatic capacitor bank

  • capacitive power factor correction for 1-35kV/50(60)Hz system

  • HVCA-15-150/75*2

  • outdoor

  • Sanhe

Availability:

PDF Export

1. Product introduction

Pole Mounted medium voltage automatic capacitor bank is widely used distribution overhead lines.It provides reasonable reactive power compensation, reduce line loss, improve power factor, improve voltage quality; It also be used for miniaturized  substation 1-35kV/50(60)Hz reactive power compensation.


1.1  Feature

1. Equipped with high-tech anti-interference power factor controller to detect the reactive power and line voltage state.

2. Setting reactive power and voltage control strategy to realize the automatic switching of high voltage shunt capacitor bank.

3. The parameters can be transferred to computer by communication port(485).

4. Optimizing and matching capacitor steps.

5. High voltage shunt capacitor with internal discharge resistance, equipped with external drop fuse, safe and reliable.

6. Adopting special vacuum contactor of switching capacitor steps, suitable for frequently switching, no resignation, no bouncing.

7. Equipped with many protection units like fuse and arrester, including bus short circuit fast break protection, capacitor electrode short circuit delay protection, capacitor overcurrent short delay protection, overvoltage protection, undervoltage protection, phase loss protection (optional when ordering) and motion rejection protection


1.2 Standards

1. IEC 60871-1:2014

2. GB/T 11024.1-2019

3. GB 50227-2017

4. GB/T 30841-2014

5. DL/T 604-2009

6. Q/RCSW 002-2005


1.3 Model Guide

2

2. Diagram

2.1 Primary Diagram( HVCA-15-150/75+75 as example)

3


TVB

big capacity voltage transformer

FV1

Distribution type zinc oxide arrester

SLC-6

Outdoor power factor controller

DR

Drop-out fuse

KM

AC high voltage vacuum contactor

C

High voltage shunt capacitor

TA1

Outdoor open type high voltage current transformer

FU

Low voltage control protects fuses

TA2

Bushing current transformer





Previous: 
Next: 

About Us

We have been specialized in power quality,EnMS and Electrical engineering. We take advantages of lean production, product design, engineering management, project service etc.

Quick Links

Product Category

Contact Us

Tel: +86-13502854349
Whatsapp: +86-13418990147
E-Mail: yvonne.zhang@samwha-cn.com

Subscribe Now

Copyright© 2023 Sanhe Power Tech (Shenzhen) Co., Ltd. All Rights Reserved.| Sitemap  | Support By Leadong